| Model |
YZC-9,YZC-9H |
YZC-968 |
YZC-990 |
YZC-992 |
YZC-991 |
YZC-993 |
YZC-994 |
YZC-995 |
| Application |
Truck scale |
Crown block scale |
Truck scale |
Truck scale |
Truck scale |
Truck scale |
Truck scale |
Truck scale |
| Capacity |
10t .20t.25t.30t.40t.50t |
10t.20t |
50klb.60klb.100klb.125klb.150klb |
10klb.15klb.20klb.25klb.30klb.40klb.50klb.60klb.75klb |
5klb.10klb.20klb.30klb.50klb.60klb.75klb.100klb.200klb.250klb |
10klb.5klb.0klb.5klb.100klb.125klb |
1klb.klb.klb.0klb.5klb.0klb.5klb |
3T.5T.7T.5T.10T |
| Rated output MV/V |
2.0±0.004 |
2.0±0.004 |
3.0±0.003 |
3.0±0.003 |
3.0±0.004 |
3.0±0.003 |
3.0±0.003 |
2.0±0.004 |
| Accuracy class |
C2 C3 |
C2 |
C2 |
C3 |
C2 C3 |
C2 |
C3 |
C2 C3 |
| Maximum number of verification intervals nmax |
2000 3000 |
2000 |
2000 |
3000 |
2000 3000 |
2000 |
3000 |
2000 3000 |
| Minimum load cell verification intervals Vmin |
Emax/5000 Emax/7500 |
Emax/5000 |
Emax/5000 |
Emax/7500 |
Emax/5000 Emax/7500 |
Emax/5000 |
Emax/7500 |
Emax/5000 Emax/7500 |
| Combined erro %RO |
≤±0.030 ≤±0.020 |
≤±0.030 |
≤±0.030 |
≤±0.020 |
≤±0.030 ≤±0.020 |
≤±0.030 |
≤±0.020 |
≤±0.030 ≤±0.020 |
| Creep %RO/30min |
0.03 0.02 |
0.02 |
0.02 |
0.02 |
0.02 0.016 |
0.02 |
0.02 |
0.02 0.016 |
| Temperature effect on sensitivity %RO / ºC |
0.003 0.0016 |
0.0016 |
0.0016 |
0.0016 |
0.0012 |
0.0016 |
0.0016 |
0.0017 |
| Temperature effect on zero %RO / ºC |
0.003 0.002 |
0.0026 |
0.0026 |
0.0026 |
0.002 0.0018 |
0.0026 |
0.002 |
0.005 0.002 |
| Zero balance %RO |
±1.0 |
±1.0 |
±1.0 |
±1.0 |
±1.0 |
±1.0 |
±1.0 |
±1.0 |
| Input resistance Ω |
725±5 2050±10(change) |
700±5 |
700±5 |
700±5 |
700±5 |
700±5 |
700±5 |
725±5 |
| Output resistance Ω |
700±5 2000±10(change) |
700±5 |
700±5 |
700±5 |
700±5 |
700±5 |
700±5 |
700±5 |
| Insulation resistance MΩ |
5000 |
5000 |
5000 |
5000 |
5000 |
5000 |
5000 |
5000 |
| Recommended excitation voltage V |
5--18 |
10--15 |
10--15 |
10--15 |
5--15 |
5--15 |
5--15 |
5--12 |
| Compensated temperature range ºC |
-10-+40 |
-10-+40 |
-10-+40 |
-10-+40 |
-10-+40 |
-10-+40 |
-10-+40 |
-10-+40 |
| Operating temperature range ºC |
-30-+70 |
-30-+70 |
-30-+70 |
-30-+70 |
-30-+70 |
-30-+70 |
-30-+70 |
-30-+80 |
| Safe overload %RO |
150 |
150 |
150 |
150 |
150 |
150 |
150 |
150 |
| Ultimate overload %RO |
250 |
200 |
300 |
300 |
200 |
300 |
300 |
200 |
| Load cell material |
Alloy steel |
Alloy steel |
Alloy steel |
Alloy steel |
Alloy steel Stainless steel |
Alloy steel stainless steel |
Alloy steel stainless steel |
Alloy steel |
| Connecting cable |
10t,20t,25t: 6.3×13m; 30t,40t:6.3×13m 6.3×15m; 50t:6.3×18m |
6.3×8m |
6.3×13m |
6.3×13m |
6.3×13m |
6.3×13m |
6.3×13m |
5.7×8m |
| Mode of Connecting wire |
Input+: Red, Input-:; Black, Output+: Green, Output-: White |